🔧 Bolts, torque and fits

How to read bolt head markings, what the torque formula really says, and the basics of clearance, transition and interference fits.

Free with an accountMillwrightMachinistHeavy Equipment Technician

Bolt grade markings

Metric class numbers read like this: the first number × 100 is the nominal tensile strength in MPa, and the number after the point × 10 is the yield as a percentage of tensile. So 10.9 means about 1000 MPa nominal tensile, with yield at 90% of that (about 900 MPa). Use nuts of a matching or higher grade or class.

Grade or classHead markingMin. tensile strength
SAE Grade 2No marks74 ksi (1/4 to 3/4 in)
SAE Grade 53 radial lines120 ksi (1/4 to 1 in)
SAE Grade 86 radial lines150 ksi
Metric 8.8"8.8"800 MPa (830 above M16)
Metric 10.9"10.9"1040 MPa
Metric 12.9"12.9"1220 MPa

Torque basics

Torque is only a way to get the bolt stretched to the right clamp load (preload). The short-form relationship is T = K × D × F: torque = nut factor × nominal diameter × target clamp load.

  • K is often taken as about 0.20 for dry, plain steel. Lubricated, plated or coated threads have a lower K. The same torque then gives much more preload, so a dry figure can overload a lubed bolt.
  • Always use the equipment maker's torque spec and sequence, including whether threads are dry or lubed. Values here are typical, for estimating only. Verify against the manufacturer.
  • Tighten in a cross pattern in stages. Use a calibrated wrench.

Fits and tolerances basics

  • Tolerance: the total amount a size may vary (upper limit − lower limit).
  • Allowance: the intended difference between mating parts at maximum material (tightest fit).
  • Clearance fit: the shaft is always smaller than the hole. Interference (press) fit: the shaft is always larger. Transition fit: it could be either.
  • ISO hole-basis examples: H7/g6 is a close running or sliding fit, H7/h6 a locational clearance fit, H7/k6 a transition fit, and H7/p6 a locational interference (press) fit. The letter sets the position of the tolerance zone and the number sets its width (grade).
  • Bearings: the ring that rotates relative to the load usually gets the interference fit. Use the bearing maker's fit tables.

⚠️ Reference only. Always verify against the manufacturer's specs, your jurisdiction's code and your site's procedures.